LDSM440
Fully-automatic Cryostat Microtome
Elevate your frozen tissue sectioning with our Fully-automatic Cryostat Microtome. Its advanced automation and precision make it the ideal choice for quick and consistent sample preparation, ensuring accurate diagnostics and research success.
- It is designed under engineering and ergonomic concepts. All the components are processed by computer numerical control.
- Retraction function prevents specimen damage from blade.
- Total thickness calculation.
- Low temperature refrigeration system with environment friendly refrigerant R404.
- Adopt UV and O3 sterilize for 30 minutes every time.
- Peltier specimen clamp refrigeration may be turned on or off manually.
- Two defrosting methods: manual and automatic.
- Two running ways: manual and automatic.
- Emergency stop function: Press the red button to stop running when any emergency happens.
- The high precision unit is enclosed outside the cryostat chamber to prevent it from thermal expansion and contraction, and keep minimum maintenance requirement.
- Artificial intelligent interface is easy for user to learn and operate.
- LCD screen can display all information including thickness, thickness sum, controlling time, temperature, timed on/off and so on.
- Sleep Function: after activating this function, the temperature in cryostat chamber can be kept between -1℃ and - 10℃; After stopping this function, the temperature in freeze chamber will rise to working temperature within 30 minutes.
- Control panel with locking function could avoid faulty operation.
- Handwheel locking function.
- Wide freezing shelf load 8 specimen cassettes simultaneously, and two of them are equipped with peltier to meet different temperatures.
Specification
of LDSM440 Fully-automatic Microtome Cryostat
Freeze chamber minimum
temperature |
-35℃±2℃ |
Freeze shelf minimum
temperature |
-45℃±5℃ |
Lowest temperature of
Peltier unit on freeze shelf |
-55℃±5℃ |
Lowest temperature of
Peltier unit on Specimen Clamp |
-50℃±5℃(working time of
Peltier is 15 minutes.) |
Maximum specimen size |
35×35mm |
Specimen vertical
stroke |
48±1mm |
Specimen horizontal
stroke |
15±0.2mm |
Coarse feeding speed |
300μm/s (slow) or
900μm/s(rapid) |
Section thickness range |
0μm~100μm adjustable; |
Trimming thickness
range |
10μm~600μm adjustable; |
Retraction range |
0~80μm adjustable, in
5μm increments |
Voltage and frequency |
220 V ± 10%, 50 HZ /
110 V ± 10%, 60 HZ |
Nominal Power |
1000 W |
Weight |
about 130 KG |
Dimensions(W×D×H) |
805×715×1195mm |